Note: Duplicate card numbers are not supported in IS2000. If a duplicate card number is imported into IS2000 the card number duplicated will be over written by the new entry. From the Access, Personnel Manager menu in IS2000 unlock the pad lock to allow editing of the module. Click on…
Adding the Bosch Driver The Bosch driver is a separately licensed feature of IS2000, licensing of a minimum of one (1) Alarm panel must have been previously purchased in order for the Bosch driver to come online. From Hardware Manager, unlock the pad lock to allow editing of the Hardware…
Here is documentation on how to arm/Disarm scripts for use in VertX IS2000/IS100. For the ARM TCP command you can use the following In Triggers and Macros IS100 and IS2000: TCP("192.168.0.179","2101","0Da110034560037^") = ([interfaceid=0][reader=0](E(2,20))) In this example the Elk panel is in IP address 192.168.0.179 we use port 2101 and the…
Authority Levels Authority Levels define what an individual user can do with the attached Bosch alarm panels, from just being to enter through a certain door to the ability to add/delete other users and change the system. All authority levels have the same events but can be turned on (activated)…
IS2000 will allow for data from existing Bosch panels to be imported.  During this process, once a panel has been imported, a .RAD file will be created for each corresponding panel.   These instructions assume the panels have already been added to IS2000 and are online. Note: Take great care…
Bosch DX4020  DX4020 Connection – RPS Flip the dip switches 1,2,3 to the down position. The remaining dip switches should be in the up position. Power down the device. Reapply power to the device. From the command prompt type telnet xxx.xxx.xxx.xxx 9999 (where xxx.xxx.xxx.xxx is the IP address of the…
Radionics® PC9000 Replacement PC9000 vs IS2000   Help and Training  Bosch IS2000 Setup    Adding the Bosch G Series in IS2000   Adding Bosch Credentials in IS2000   IS2000-  G Series Training Curriculum   Supported Firmware GV3 8.11+ and everything newer GV4 v1.xx.xx GV4 v2.xx  (Mode 1)    Mode 1 Maximums D7212GV3 4…
DMP First Man In Disarm Programming: 1- Make sure the DMP and IS2000 are running and Online and preconfigured. 2- Select the Door that will be used to disarm the DMP. Typically is the front main door. 3- Select the Reader under the APC 2R that correspond to the main…
Programming the ELK Panel Program your ELK controller(s) to send events automatically to the host: Enter the Installer Programming mode: Press "ELK" key + 9 (menu 9) followed by the Right arrow key.  Enter the default Installer code of 172839 when prompted.  Display should read: "01 - Bus Module Enrollment" …
Supported Features Virtually unlimited number of users (host dependent). Arm / Disarm of Areas Activate / Deactivate outputs Real-time status of outputs / inputs using Point Status Cross platform activation using the Mercury hardware platform and Triggers / Macros Graphic Maps Arm / Disarm areas from graphic maps Activate /…
Modifying the Template File The EST- Fire Panel Driver will parse event strings that are outputted from the serial printer port of the fire panel.  These events can be assigned to virtual addresses that can be plotted on the Graphic Maps module and/or logged to appear as either Events and/or…
  Features PC9000 IS2000 Attendance Reporting Add-on Module Scheduled Backup Feature Multi-Monitor Support Re-sizable Graphical User Interface (GUI) Device Level Permissions Custom Report Templates Custom Report Designer Google Earth Support 3D Graphic Map Support Multi-site management with unlimited zoom SDK for Third Party Integration Guard Tour Add-On Module Email Reporting…