Bosch G Series Integration

Bosch G Series Integration

Note: Duplicate card numbers are not supported in IS2000. If a duplicate card number is imported into IS2000 the card number duplicated will be over written by the new entry. From the Access, Personnel Manager menu in IS2000 unlock the pad lock to allow editing of the module. Click on…
Adding the Bosch Driver The Bosch driver is a separately licensed feature of IS2000, licensing of a minimum of one (1) Alarm panel must have been previously purchased in order for the Bosch driver to come online. From Hardware Manager, unlock the pad lock to allow editing of the Hardware…
Authority Levels Authority Levels define what an individual user can do with the attached Bosch alarm panels, from just being to enter through a certain door to the ability to add/delete other users and change the system. All authority levels have the same events but can be turned on (activated)…
IS2000 will allow for data from existing Bosch panels to be imported.  During this process, once a panel has been imported, a .RAD file will be created for each corresponding panel.   These instructions assume the panels have already been added to IS2000 and are online. Note: Take great care…
Bosch DX4020  DX4020 Connection – RPS Flip the dip switches 1,2,3 to the down position. The remaining dip switches should be in the up position. Power down the device. Reapply power to the device. From the command prompt type telnet xxx.xxx.xxx.xxx 9999 (where xxx.xxx.xxx.xxx is the IP address of the…
Radionics® PC9000 Replacement PC9000 vs IS2000   Help and Training  Bosch IS2000 Setup    Adding the Bosch G Series in IS2000   Adding Bosch Credentials in IS2000   IS2000-  G Series Training Curriculum   Supported Firmware GV3 8.11+ and everything newer GV4 v1.xx.xx GV4 v2.xx  (Mode 1)    Mode 1 Maximums D7212GV3 4…
  Features PC9000 IS2000 Attendance Reporting Add-on Module Scheduled Backup Feature Multi-Monitor Support Re-sizable Graphical User Interface (GUI) Device Level Permissions Custom Report Templates Custom Report Designer Google Earth Support 3D Graphic Map Support Multi-site management with unlimited zoom SDK for Third Party Integration Guard Tour Add-On Module Email Reporting…
Skeds The Skeds module will allow the operator to configure schedules for items such as automatic door unlocks. To access the Skeds Module click on the Access, Sked Manager Menu item. Unlock the module to allow editing of the screen. To unlock the module click on the pad lock located…
Panel Commands SETDATETIME SILENCEBELL   User Database Commands UPDATEUSERNAME UPDATETOKENTABLE UPDATEUSERCLASS BULKUSERNAMEUPDATE BULKTOKENTABLEUPDATE BULKUSERCLASSUPDATE READUSERNAMES READUSERCLASSES READTOKENTABLES READUSERNAMES READUSERCLASSES READAUTHORITYLEVELS   Skeds Database UPDATESKED READSKEDS SETHOLIDAY READHOLIDAYS   Monitor Point Commands BYPASSPOINT GETPOINTTEXT SETPOINTTEXT BULKPOINTTEXTUPDATE READPOINTTEXTALL   Door Commands DOORCOMMAND GETDOORAREAS   Realy Commands SETONBOARDRELAY SETOFFBOARDRELAY   Area Commands ARMAREA…
Hardware Easy Configuration – Manually add device, programming requires only the IP address of the controller – Driver must be restarted after this process. Partitioning can be performed to the device level. Hardware Tree can be sorted alphabetically or numerically, sort order follows through out the application. Find option available…