Of the many keypad configurations present, the two that work best with IS2000 include: 1. 8 bit message (Dorado) 2. Standard 26 bit output Outlined below are the applicable reader modes and the corresponding IS2000 fields (personnel manager) based on the two keypad configurations and the hardware platforms. SCP-2/EPC-1 8…
Restore Selected Controllers to Last Known State when Driver Starts If this driver property is set to 'True', then all controllers that have the controller property 'Restore to Last Known State after Reset' set to 'True' will restore the last known state of the controller's reader modes, output relays, and…
Lenel Database Import function is built into the Data Import Utility.  This can import Hardware, Access Levels, Personnel records, and Personnel photos; however, Lenel has 3 different database versions.For all database conversions, we will need to have the database in-house for evaluation.  Once the customer agrees to the cost and…
Settings -> Log Manager Enabling / Disabling Events From the Settings -> Log Manager Menu click on the pad lock to allow editing of the Log Manager screen. Enter the name of the event to modify in the Find text box. With the event highlighted, click on the drop down…
General Infomation about the Magnetic Stripe Card In most magnetic stripe cards, the magnetic stripe is contained in a plastic-like film. The magnetic stripe is located 0.223 inches (5.66 mm) from the edge of the card, and is 0.375 inches (9.52 mm) wide. The magnetic stripe contains three tracks, each…
Device Groups / Areas will allow for any combination of grouped points in a Device Group / Area to be disarmed, unlocked, armed, or locked manually and will control all devices in the group once the command has been sent. Click on the Access menu and click on Device Groups…
MEMORY ALLOCATION for SCP Compact & Expanded boards A)  Precision Access set to TRUE # Of Cards                   % of free memory Allocated                   on the Controller SCP-C         1000----------------------------------34%     …
For nearly 20 years Mercury Security has steadfastly practiced the singular art of building access control hardware.   Since 1992 in collaboration with OEM partners like IMRON Corporation, we have built an unmatched set of features into an Open hardware platform that is unequaled for reliability, longevity and effectiveness…
Add the following properties and values to the RemotePath\Drivers\12000.ini file under the section [Controller_1.0] where 1.0 represents the controller's address.  Please note that you will need to make sure that properties and values listed below must be in each controller's section.: ;enable the dual port features for this controller (0=disabled …
Trigger Definitions Description:  Text field to describe what the Trigger does. Events:  The event that will trigger the Macro. Address:  The specific address for where the Event occurred.  Based on the Event, you can select (ALL) for addresses in the controller or a specific address. Trigger Code:  A Trigger Code…
Drive Gate Settings Input Supervision for input 1: 0 normally closed Input Supervision for input 2: 1 normally open Note: If input 1 and/or input 2 are red, in the hardware properties, then check wiringDefault reader mode: Card Only (for both readers) Door Held Time, Door Contact Input 2: 50 seconds Output 1 Pulse…
Here are the general Access 97/2000 characteristics: Access Object Maximum sizes/numbers No. of concurrent users 255 No. of fields in a table 255 Database size 1 GB No. of characters in an object name 64 No. of characters in a password 14 No. of characters in a user name or…