Sku: H-V1000

VertX EVO V1000 Controller

 Datasheet

 

Overview

The HID VertX products provide a complete and fully featured hardware/firmware infrastructure to UnityIS or IS2000, communicating via industry standard TCP/IP protocol, over 10/100 Mbps Ethernet or the Internet. The V1000 boasts a 32-bit RISC processor running the Linux Operating System. On-board flash memory allows program updates to be downloaded via the network. The V1000 connects up to 32 Door/Reader, Input Monitor, or Output Control Interfaces via two independent RS-485 networks, each network having two sets of input connections for optimum system topology. This architecture minimizes the impact on corporate LANs by using only one TCP/IP address for every 32 interfaces, and by handling low-level transactions on the RS-485 network.

 

VertX EVO V1000 Controller/Up to 64 Doors

Expandable System Controller that communicates to and controls Sub-Controllers, Connects to H-V100, H-V200, and/or H-V300, includes 2 supervised inputs, 2 non-latching output relays, Tamper Input, AC & Battery Fail Inputs (maximum of 32 Sub-Controllers per Controller) 5000 Event Buffer, 250,000 Card Population.

 

Key Features

  • Stores a complete access control and configuration database for up to 32 Reader Interfaces (up to 64 doors) and 44,000 cardholders with expansion capability up to 250,000 cardholders.
  • The access control system interfaces with combinations of devices with a maximum of:
    • 32 Door/Reader interfaces (up to 64 doors/readers) or
    • 32 input monitor interfaces 9 (up to 512 monitor points) or
    • 32 output control interfaces (up to 384 control relays)
  • Reports supervised inputs/alarms with 255 priorities.
  • Includes an HTTP API, Windows® DLL API, and direct communication API.
  • Allows local connection of a laptop computer for diagnostics and configuration.
  • Connects to the host and other devices on a TCP/IP network.
  • Receives and processes real time commands from the host software application.
  • Reports all activity to the host.
  • Controls and communicates with all connected devices.
  • Buffers offline transactions and uploads to the host when communication is restored.
  • Allows fallback communications via dialup or RF modem if TCP/IP network communication is lost.
  • UL 294 and UL 1076 recognized component.

 

Dimensions 

5.8' W x 4.825' H x 1.275' D (147.32 mm x 122.55 mm x 32.38 mm)

 

Weight

12.4 oz (.35 kg)

 

Power Supply Requirements 

140 mA @ 12-18 VDC 

 

Cable Distance 

RS-485 – 4000 feet per network (two independent RS-485 networks) using Belden 3105 (22AWG) 2-twisted pair, shielded 100Ω cable 

TCP/IP – 300 feet (100 m) to next device, using Category 5 cable, Alpha 9504C or 9504F 

Input Circuits – 500 feet (150 m), 2-conductor, shielded, using ALPHA 1292C (22AWG) or Alpha 2421C (18AWG) 

Output Circuits – 500 feet (150 m), 2-conductor, using ALPHA 1172C (22AWG) or Alpha 1897C (18AWG) Minimum wire gauge depends on cable length and current requirements.

 

Operating Environment 

Indoors, or customer-supplied NEMA-4 Enclosure

 

Temperature 

32° to 122° F (0° to 50° C)

 

Humidity 

5% to 95% relative, non-condensing

 

Communication Ports 

RS-485 – two wire. 

TCP-IP – one port, 10 or 100 Mbps

 

Certifications 

UL 294 and UL 1076 Recognized Component for the US 

CSA 205 for Canada 

FCC Class A Verification 

EMC for Canada, EU (CE Mark), Australia (C-Tick Mark), 

New Zealand, Japan 

EN 50130-4 Access Control Systems Immunity for the EU (CE Mark)